“150”, Aptitude Test Questions and Answers for Artisan Grade II (Electrical) – TANESCO.

 

“150”, Aptitude Test Questions and Answers for Artisan Grade II (Electrical) – TANESCO.

 

ABSTRACT

This aptitude test preparation guide contains 150 multiple-choice questions and answers designed for candidates applying for the position of Artisan Grade II – Electrical at the Tanzania Electric Supply Company Limited (TANESCO). It covers essential electrical trade knowledge, including electrical installation, electrical measurements, motor operation, transformers, circuit protection, fault diagnosis, preventive maintenance, and electrical safety. Each question is accompanied by a correct answer and an explanatory rationale to help candidates understand key technical concepts and apply them to practical workplace situations. The guide aims to strengthen candidates’ technical knowledge, problem-solving skills, and confidence in preparing for aptitude tests. It serves as a revision resource to support effective preparation for recruitment assessments and the practical responsibilities associated with electrical maintenance work.

 

Prepared for: Candidates applying for Artisan Grade II (Electrical) – TANESCO

Independent aptitude-test preparation resource; not an official TANESCO publication.

0628729934.

Date: October 29, 2026

 

Dear applicants,

This collection of 150 multiple-choice questions and answers is designed to help candidates revise electrical trade knowledge relevant to aptitude tests and recruitment assessments for Artisan Grade II (Electrical) – TANESCO. It is an independent preparation resource, not an official TANESCO examination paper, and it does not guarantee that any question will appear in a recruitment assessment. I wish you success in your preparation and recruitment process!

 

Warm regards,

Artisan Grade II (Electrical) – TANESCO Aptitude Test Preparation Guide

 

Independent aptitude-test preparation guide for candidates applying for Artisan Grade II (Electrical) – TANESCO. Not an official TANESCO publication.

Artisan Grade II (Electrical) – TANESCO.

150 Aptitude Test Questions and Answers


Question 1

During preventive maintenance of a distribution panel, an artisan discovers that a circuit breaker trips repeatedly after operating for approximately 20 minutes under normal working conditions. The connected equipment appears to function normally before the breaker trips. Which action would provide the most useful initial evidence for determining the cause of the repeated tripping?

A. Measure the circuit current under operating conditions and compare it with the protective device rating and expected load.  B. Replace the circuit breaker with one of a higher current rating and observe whether the circuit remains operational.  C. Disconnect the protective earth conductor temporarily and check whether the circuit breaker continues to trip.  D. Tighten all accessible terminals immediately and restore the circuit without recording the initial operating conditions.

Answer: A. Measure the circuit current under operating conditions and compare it with the protective device rating and expected load.

Rationale: Measuring the operating current and comparing it with the circuit breaker's rating is an appropriate initial diagnostic step because repeated tripping after a period of operation may indicate sustained overload, excessive equipment demand, or another condition that causes the protective device to operate as it heats up. The measurement helps establish whether the current exceeds the expected operating range and guides subsequent investigation. Replacing the breaker with a higher-rated device without verifying conductor capacity and circuit design could leave the circuit inadequately protected. Disconnecting the protective earth conductor would create a dangerous condition and would not establish the cause of ordinary overcurrent tripping. Tightening terminals may eventually be necessary if a loose connection is identified, but indiscriminate intervention before recording and investigating the symptoms can obscure the original fault.


Question 2

An artisan is instructed to test the insulation resistance of an electrical installation using an insulation resistance tester. Which procedure is most appropriate before applying the test voltage?

A. Switch off the installation's main switch but leave sensitive electronic equipment connected to the circuit.  B. Isolate the circuit, verify that it is de-energised, and disconnect or protect equipment that could be damaged by the test voltage.  C. Leave the circuit energised and connect the tester across the conductors to identify insulation deterioration.  D. Disconnect the protective earth conductor and use the tester between the phase conductor and the neutral conductor while the circuit remains connected to its supply.

Answer: B. Isolate the circuit, verify that it is de-energised, and disconnect or protect equipment that could be damaged by the test voltage.

Rationale: Insulation resistance testing involves applying a test voltage that can damage sensitive electronic devices, surge-protection components, and other equipment that is not suitable for the test. The circuit must therefore be isolated from its supply, and the absence of voltage must be verified using an appropriate method before testing begins. Equipment that could be affected by the test voltage must be disconnected or protected in accordance with the manufacturer's instructions and the applicable testing procedure. Switching off a main switch alone does not establish that every conductor is safely isolated, particularly where alternative supplies or backfeeding may exist. Applying an insulation resistance test to an energised circuit is unsafe, while disconnecting the protective earth conductor does not make an energised test acceptable. After testing, the circuit must also be discharged as required before it is handled or returned to service.


Question 3

A technician measures the voltage at the supply terminals of an electrical motor and obtains the expected value. However, when the motor starts, its terminals show a substantial voltage reduction and the motor struggles to accelerate. Which explanation is most consistent with these observations?

A. The motor's insulation resistance has necessarily increased, preventing the normal flow of starting current.  B. The supply frequency has necessarily increased, causing the motor to demand less torque during acceleration.  C. Excessive voltage drop under starting load may result from supply impedance, undersized conductors, or a high-resistance connection.  D. The motor's protective earth conductor is necessarily disconnected, preventing the supply voltage from reaching the motor windings.

Answer: C. Excessive voltage drop under starting load may result from supply impedance, undersized conductors, or a high-resistance connection.

Rationale: A motor draws substantial current during starting, and the impedance of the supply network and conductors produces a voltage drop proportional to the current flowing through that impedance. If the conductors are undersized, a terminal connection has excessive resistance, or the supply impedance is unusually high, the voltage at the motor terminals may fall significantly during acceleration. Reduced terminal voltage can impair starting torque and prolong acceleration, potentially causing the motor to draw elevated current for longer than expected. The normal voltage measured before starting does not rule out these problems because the voltage drop may become apparent only under load. Increased insulation resistance does not necessarily explain the observed behaviour, increased supply frequency cannot be inferred from the voltage readings, and a disconnected protective earth conductor does not normally prevent the motor's phase-to-phase or phase-to-neutral supply voltage from reaching its windings.


Question 4

During inspection of a single-phase electrical installation, an artisan measures the expected voltage between phase and neutral at a socket outlet. However, the connected appliance operates intermittently, and the measured voltage changes when the plug is moved slightly. Which fault should be investigated first?

A. An incorrectly rated circuit breaker that trips when the appliance draws its normal operating current.

B. A defective appliance heating element that causes excessive current whenever the appliance operates.

C. A loose connection in the fixed wiring supplying the socket outlet.

D. A loose or damaged contact in the socket outlet or plug connection that interrupts the supply intermittently.

Answer: D. A loose or damaged contact in the socket outlet or plug connection that interrupts the supply intermittently.

Rationale: An appliance that operates intermittently when its plug is moved suggests a mechanical contact problem in the plug, socket outlet, or associated termination. A loose or damaged contact can interrupt current flow and may also produce local heating, arcing, and further deterioration. The fact that the voltage changes when the plug moves is particularly important because it connects the symptom to a physical disturbance of the connection. The artisan should isolate the circuit safely, inspect the relevant contacts and terminations, and carry out appropriate tests before returning the installation to service. An incorrectly rated circuit breaker would not ordinarily respond directly to movement of the plug, while an appliance heating-element fault or a supply-frequency problem would not normally explain a voltage change specifically associated with moving the plug. The installation should not remain in service while the intermittent contact fault is unresolved.


Question 5

A preventive maintenance inspection reveals that a motor terminal connection has developed discolouration and signs of overheating. The motor continues to operate, and its measured current is within the expected range. What is the most appropriate maintenance response?

A. Isolate the equipment, inspect the affected connection and associated components, correct the defect, and verify the connection before returning the motor to service.  B. Increase the motor's overload protection setting to prevent the terminal from heating during normal operation.  C. Continue operating the motor because a normal current measurement establishes that the terminal connection is safe.  D. Replace the motor winding immediately because terminal discolouration confirms that the winding insulation has failed.

Answer: A. Isolate the equipment, inspect the affected connection and associated components, correct the defect, and verify the connection before returning the motor to service.

Rationale: Discolouration and overheating at a terminal connection are warning signs of a potentially unsafe electrical defect, even when the motor's measured current is within its expected range. A loose termination, damaged contact surface, contamination, oxidation, or an unsuitable connection can create localised resistance and heating without producing an obvious overall overcurrent condition. The appropriate response is to isolate the equipment, verify that it is safe to work on, investigate the affected connection, and correct the identified defect using the manufacturer's requirements and applicable procedures. The connection and surrounding components should then be checked before the motor is returned to service. Increasing the overload setting would not correct a high-resistance connection and could compromise protection. Continued operation ignores a warning sign, while terminal discolouration alone does not establish that the motor winding has failed.


Question 6

An artisan uses a digital multimeter to investigate a circuit that is suspected of containing a broken conductor. The circuit is isolated and verified as de-energised. When the meter is set to resistance, it displays an overload indication rather than a numerical resistance value. What is the most appropriate interpretation?

A. The circuit necessarily contains a short circuit because the meter cannot display the resistance numerically.  B. The resistance between the selected test points exceeds the meter's measurable range or the circuit presents an open path.  C. The circuit necessarily has correct continuity because an overload indication represents zero resistance.  D. The circuit must be supplied with a higher voltage before a resistance measurement can be completed.

Answer: B. The resistance between the selected test points exceeds the meter's measurable range or the circuit presents an open path.

Rationale: On many digital multimeters, an overload indication in resistance mode means that the measured resistance exceeds the selected range or that no conductive path is detected between the test points. In an isolated circuit being investigated for a broken conductor, an open circuit is therefore a plausible explanation. However, the indication alone does not identify the exact physical location of the fault, and the artisan should confirm that the leads are correctly connected, the meter is functioning properly, and the selected test points are appropriate. A short circuit normally produces a very low resistance reading rather than an overload indication. An overload indication does not represent zero resistance, and applying supply voltage to a circuit is not the correct way to complete an ordinary resistance measurement. Further continuity checks at suitable points can help locate the interruption.


Question 7

A technician tests an isolated cable using an ohmmeter and finds that the resistance between its two ends is substantially higher than expected. The cable length and conductor size are known, and the test leads have been checked. Which condition is the most plausible explanation?

A. The cable's conductor has developed a lower resistance because its cross-sectional area has increased.  B. The cable's insulation resistance has necessarily fallen to zero between the phase conductor and earth.  C. Corrosion, conductor damage, or a poor termination may have increased the resistance along the measured path.  D. The supply frequency has changed sufficiently to increase the cable's measured DC resistance substantially.

Answer: C. Corrosion, conductor damage, or a poor termination may have increased the resistance along the measured path.

Rationale: The resistance of a conductor depends on its material, length, cross-sectional area, and temperature. For a cable of known length and conductor size, a resistance substantially above the expected value may indicate damaged conductor strands, corrosion, an unsuitable joint, or a poor termination within the measured path. Checking the test leads helps reduce the possibility that the result is caused by the measuring arrangement, although lead resistance and instrument limitations should still be considered when measuring very low resistances. A low insulation resistance is a different property measured between conductors or between a conductor and earth using an appropriate insulation test. A reduction in conductor cross-sectional area would generally increase resistance rather than decrease it. Supply frequency does not ordinarily explain a substantial increase in the DC resistance indicated by an ohmmeter.


Question 8

During maintenance of an electrical installation, a circuit is found to have a protective earth conductor that appears physically intact. Which test provides the most direct evidence that the protective conductor forms an effective, low-resistance path between the relevant protective connection points?

A. Measure the phase-to-neutral supply voltage while the circuit is carrying its normal operating load.  B. Measure the insulation resistance between the phase conductor and the neutral conductor.  C. Measure the current consumed by the connected appliance and compare it with its rated current.  D. Perform a protective-conductor continuity test using a suitable low-resistance test instrument and appropriate test points.

Answer: D. Perform a protective-conductor continuity test using a suitable low-resistance test instrument and appropriate test points.

Rationale: A protective-conductor continuity test directly assesses whether an electrically continuous path exists through the protective conductor and its relevant connections. A conductor can appear physically intact while a terminal is loose, a joint is corroded, or a concealed section is damaged, so visual inspection alone cannot establish effective electrical continuity. A suitable low-resistance test instrument and appropriate test points help establish whether the measured resistance is consistent with an effective protective path. Measuring phase-to-neutral voltage assesses a different aspect of the circuit, while an insulation resistance test between phase and neutral does not directly establish protective-earth continuity. Measuring appliance current likewise provides no direct proof that the protective conductor is continuous. The result should be interpreted against the applicable installation requirements and the circuit's design.


Question 9

A technician is checking a single-phase resistive heater rated at 2,300 W and designed for a 230 V supply. Assuming the heater operates at its rated voltage and its resistance remains approximately constant, what current should it draw during normal operation?

A. 10 A, calculated by dividing the rated power by the rated voltage.  B. 0.1 A, calculated by dividing the rated voltage by the rated power.  C. 5 A, calculated by dividing the rated power by twice the rated voltage.  D. 20 A, calculated by dividing twice the rated power by the rated voltage.

Answer: A. 10 A, calculated by dividing the rated power by the rated voltage.

Rationale: For a resistive heater operating at its rated voltage, electrical power is given by \(P = VI\), where \(P\) is power in watts, \(V\) is voltage in volts, and \(I\) is current in amperes. Rearranging gives \(I = P/V\). Substituting the stated values produces \(I = 2,300/230 = 10\text{ A}\). The heater should therefore draw approximately 10 A under the stated conditions. The other values result from incorrect arithmetic or inappropriate manipulation of the power equation. This calculation is useful when checking whether measured current is broadly consistent with an appliance's rating, although actual readings may vary with supply voltage, temperature, and the characteristics of the connected equipment.


Question 10

An artisan measures a supply voltage of 230 V at a socket outlet while no appliance is connected. After a 2,300 W resistive appliance is connected, the measured voltage at the same outlet falls to 218 V. Assuming the appliance behaves approximately as a constant-resistance load over this voltage range, which conclusion is most appropriate?

A. The voltage reduction proves that the supply frequency has fallen by approximately the same percentage.  B. The voltage reduction suggests that the supply path has appreciable impedance and warrants investigation under load.  C. The voltage reduction proves that the appliance has developed an insulation fault to its protective earth conductor.  D. The voltage reduction establishes that the circuit's protective device is incorrectly rated for the appliance.

Answer: B. The voltage reduction suggests that the supply path has appreciable impedance and warrants investigation under load.

Rationale: The reduction from 230 V to 218 V when the appliance is connected indicates that the voltage at the socket is lower under load than under no-load conditions. This can occur because current flowing through the impedance of supply conductors, connections, or the upstream network produces a voltage drop. The observation warrants further investigation, particularly if the reduction exceeds the applicable installation requirements or causes equipment to malfunction. The measurement alone does not establish whether the cause is undersized conductors, a poor connection, excessive upstream impedance, or another supply problem. It also does not demonstrate a change in frequency, prove an insulation fault, or establish that the protective device is incorrectly rated. Additional measurements at appropriate points, carried out safely, can help determine where the voltage drop originates.


Question 11

An artisan is diagnosing a three-phase motor that hums when a start command is given but fails to accelerate. The motor's supply and control arrangements require further investigation. Which condition is an important possibility to check before concluding that the motor itself is mechanically defective?

A. A higher-than-normal insulation resistance that necessarily prevents the motor from developing its rated rotational speed.  B. A correctly balanced three-phase supply that always prevents a motor from starting under mechanical load.  C. Loss of one supply phase or a fault in the starting circuit that prevents normal motor acceleration.  D. An increased protective-earth conductor size that necessarily reduces the current available to the motor windings.

Answer: C. Loss of one supply phase or a fault in the starting circuit that prevents normal motor acceleration.

Rationale: A three-phase motor that hums but does not accelerate may be experiencing single-phasing, a missing supply phase, a defective contactor contact, an open circuit in the starting arrangement, or another electrical fault that prevents the motor from receiving the intended supply. Depending on the motor design and starting method, such conditions can produce abnormal current, reduced torque, overheating, and failure to start. The artisan should follow an appropriate diagnostic sequence, checking the supply and control circuit safely before attributing the problem to mechanical failure. A balanced supply ordinarily supports normal motor operation rather than preventing it. High insulation resistance does not inherently prevent acceleration, and increasing the protective-earth conductor size does not ordinarily reduce the current available to the motor windings. The exact fault must be established through suitable tests.


Question 12

A maintenance team is preparing a preventive maintenance schedule for electrical equipment in a facility. Which approach is most likely to reduce unexpected breakdowns while making effective use of maintenance resources?

A. Inspect every item of equipment at the same fixed interval, regardless of operating conditions or failure history.  B. Schedule maintenance only after equipment has failed, using previous breakdowns to determine which parts require replacement.  C. Replace all electrical components annually, even when inspection and operating records indicate that they remain serviceable.  D. Set maintenance intervals according to equipment criticality, manufacturer guidance, operating conditions, observed deterioration, and failure history.

Answer: D. Set maintenance intervals according to equipment criticality, manufacturer guidance, operating conditions, observed deterioration, and failure history.

Rationale: An effective preventive maintenance schedule considers the consequences of equipment failure, the manufacturer's maintenance recommendations, the operating environment, the equipment's duty cycle, and evidence from previous inspections and breakdowns. Equipment exposed to dust, moisture, vibration, high temperatures, or frequent switching may require different attention from equipment operating under less demanding conditions. Critical equipment may also warrant more frequent inspection because failure could interrupt an essential service or create a safety risk. Applying the same interval to every item can waste resources on some equipment while leaving other equipment inadequately maintained. Replacing components automatically without evidence of need can introduce new defects and unnecessary costs, while waiting for failure is primarily a reactive approach rather than preventive maintenance. Maintenance records should be used to improve future scheduling and identify recurring problems.


Question 13

A technician is investigating a lighting circuit in which several lamps supplied by the same circuit have become unusually dim. The lamps are compatible with the installation, and the symptom began after maintenance work was performed on a nearby junction box. Which investigation is most appropriate?

A. Check for a loose or high-resistance connection and measure voltage at suitable points under operating conditions.  B. Replace all the lamps immediately because simultaneous dimming confirms that every lamp has reached the end of its service life.  C. Increase the circuit breaker's rating because a higher rating will restore the voltage available to the lamps.  D. Disconnect the protective earth conductor because it normally carries the current required to maintain lamp brightness.

Answer: A. Check for a loose or high-resistance connection and measure voltage at suitable points under operating conditions.

Rationale: Several lamps becoming dim simultaneously suggests that a shared part of the supply path may be affected. Because the symptom began after nearby maintenance, a disturbed terminal, loose joint, or other high-resistance connection should be considered. Measuring voltage at appropriate points under operating conditions can help identify where the abnormal voltage drop occurs. The investigation must be carried out using safe isolation and testing procedures appropriate to each measurement. Simultaneous dimming does not establish that all lamps have failed independently, and increasing the circuit breaker's rating does not correct a poor connection or restore the proper supply voltage. The protective earth conductor is intended for protection against electric shock and fault conditions, not as a normal return path for lamp operating current.


Question 14

A technician is testing an isolated capacitor using a digital multimeter set to resistance mode. After ensuring that the capacitor is safely discharged and disconnected as necessary to prevent interference from parallel circuit paths, the technician observes that the resistance reading initially changes before becoming very high. Assuming the meter is connected in a configuration that allows the capacitor to charge, which explanation best accounts for this behaviour?

A. The capacitor is necessarily short-circuited because its apparent resistance changes during the measurement.
B. The meter initially charges the capacitor, causing the measured current to decrease as the capacitor's voltage rises.
C. The circuit's supply frequency increases as the capacitor charges, causing the resistance reading to rise.
D. The capacitor necessarily develops a permanent open circuit immediately after the first meter reading.

Answer: B. The meter initially charges the capacitor, causing the measured current to decrease as the capacitor's voltage rises.

Rationale: When a resistance meter is connected across a capacitor in a suitable circuit, the meter's internal source may cause current to flow as the capacitor charges. As the capacitor voltage rises towards the meter's applied voltage, the charging current decreases, and the instrument may display a resistance that increases with time. A high final reading can therefore be consistent with normal capacitor-charging behaviour, depending on the circuit and instrument used. However, this observation alone does not establish that the capacitor is in good condition; additional tests may be required to assess capacitance, leakage, or other characteristics. A changing resistance reading does not itself prove a short circuit, a permanent open circuit, or a change in supply frequency. The capacitor must be safely discharged before testing and handled according to the appropriate safety procedures.


Question 15

An artisan is instructed to investigate a circuit breaker that trips immediately when a particular circuit is energised. The circuit has been isolated and made safe for appropriate testing. Which finding would most strongly support the possibility of a short circuit between current-carrying conductors?

A. An insulation resistance reading between the relevant conductors that is very high and stable.  B. A protective-conductor continuity result that is consistent with the expected low-resistance path.  C. An abnormally low resistance between the relevant isolated conductors after connected equipment and parallel paths have been accounted for.  D. A normal phase-to-neutral voltage measured at an unrelated socket outlet on a separate circuit.

Answer: C. An abnormally low resistance between the relevant isolated conductors after connected equipment and parallel paths have been accounted for.

Rationale: A short circuit between current-carrying conductors creates an unintended low-resistance path that can produce a large fault current when the circuit is energised. With the circuit isolated, suitable connected equipment and parallel paths accounted for, an abnormally low resistance measurement between the relevant conductors can support the diagnosis of a short circuit. The measurement must be interpreted carefully because connected components may legitimately produce low resistance, and the test arrangement can affect the result. A high insulation resistance between conductors would generally indicate good insulation rather than a short circuit. Protective-conductor continuity is a separate property, and a normal voltage reading on an unrelated circuit does not establish the condition of the circuit under investigation. The actual fault location should be confirmed through systematic testing before repairs are completed.


Question 16

A single-phase electrical installation uses a 230 V supply to operate a resistive load drawing 8 A. Assuming the load operates at the stated voltage and its power factor is unity, what is its electrical power consumption?

A. 29 W, obtained by dividing the supply voltage by the current.  B. 1,150 W, obtained by dividing the product of voltage and current by two.  C. 1,840 kWh, obtained by multiplying the voltage by the current and expressing the result as energy.  D. 1,840 W, obtained by multiplying the supply voltage by the current.

Answer: D. 1,840 W, obtained by multiplying the supply voltage by the current.

Rationale: For a single-phase resistive load with a power factor of unity, the electrical power is calculated using \(P = VI\). Substituting the stated values gives \(P = 230 \times 8 = 1,840\text{ W}\), equivalent to 1.84 kW. The result represents power, which is the rate at which electrical energy is consumed, rather than energy itself. Energy would depend on how long the load operates; for example, a 1.84 kW load operating continuously for one hour consumes 1.84 kWh. Dividing voltage by current does not calculate power, and halving the voltage-current product is not justified by the stated conditions. Distinguishing between watts and kilowatt-hours is important when interpreting equipment ratings, electricity consumption, and maintenance measurements.


Question 17

During an inspection, an artisan finds that a circuit's fuse has ruptured. Before replacing it, the artisan needs to determine whether the fuse operated because of a temporary abnormal condition or an unresolved fault. Which approach is most appropriate?

A. Identify and investigate the cause of operation, verify the circuit and load condition, and fit a replacement fuse of the specified type and rating only when safe.  B. Install a fuse with twice the original current rating to prevent a repeat interruption during the next operating cycle.  C. Bridge the fuse terminals temporarily with a conductor and observe whether the connected equipment resumes normal operation.  D. Replace the fuse with any available fuse of the same physical size because physical compatibility establishes electrical suitability.

Answer: A. Identify and investigate the cause of operation, verify the circuit and load condition, and fit a replacement fuse of the specified type and rating only when safe.

Rationale: A ruptured fuse indicates that sufficient current or another relevant operating condition caused the fuse element to open. Before replacing it, the artisan should investigate possible causes such as overload, short circuit, defective equipment, or an abnormal transient where relevant. The circuit must be made safe, and appropriate checks should be completed before restoring the supply. Any replacement must conform to the specified current rating, breaking capacity, fuse characteristics, and circuit design. Installing a higher-rated fuse without confirming the circuit's requirements can allow conductors or equipment to overheat before the fuse operates. Bridging the fuse removes an important protective function and creates a serious hazard. Physical size alone does not establish that a fuse is electrically suitable for the application.


Question 18

A technician is asked to verify that a circuit breaker can interrupt an excessive current under the conditions expected at the installation. Which specification is particularly important when assessing whether the device can safely interrupt a prospective short-circuit current?

A. The normal operating voltage of the smallest appliance connected to the installation.  B. The circuit breaker's rated short-circuit breaking capacity relative to the prospective fault current at its installation point.  C. The resistance of the protective earth conductor measured without considering the installation's fault conditions.  D. The number of switching operations performed by the circuit breaker during its most recent maintenance period.

Answer: B. The circuit breaker's rated short-circuit breaking capacity relative to the prospective fault current at its installation point.

Rationale: A circuit breaker's rated short-circuit breaking capacity indicates the level of short-circuit current it is designed to interrupt safely under its specified operating conditions. The prospective fault current at the installation point must not exceed the device's applicable breaking capacity, and the protective device must also be suitable for the circuit's voltage, system arrangement, and required protective characteristics. A breaker with inadequate breaking capacity may fail to interrupt a severe fault safely, even if its normal current rating appears appropriate. The smallest appliance's operating voltage does not establish the fault-current level, and protective-conductor resistance alone cannot establish the breaker's interrupting capability. Switching history may inform maintenance decisions, but it does not replace verification of the prospective fault current and the device's rated breaking capacity.


Question 19

An artisan measures the resistance of a copper conductor while it is cold and then repeats the measurement after the conductor has become significantly warmer. Assuming the conductor remains physically unchanged and the measurements are performed correctly, what result is generally expected?

A. Its resistance decreases because heating increases the number of available conduction paths in copper.  B. Its resistance remains exactly constant because conductor temperature affects insulation but not metal resistance.  C. Its resistance increases because copper has a positive temperature coefficient of resistance over ordinary operating temperatures.  D. Its resistance becomes zero because thermal expansion removes the electrical resistance between the conductor's ends.

Answer: C. Its resistance increases because copper has a positive temperature coefficient of resistance over ordinary operating temperatures.

Rationale: Copper is a metal with a positive temperature coefficient of resistance over ordinary electrical operating temperatures. As its temperature rises, increased lattice vibrations impede the movement of charge carriers, causing the conductor's resistance to increase. For many practical calculations over a moderate temperature range, the resistance change can be approximated using \(R_T = R_0[1+\alpha(T-T_0)]\), where \(R_0\) is the resistance at the reference temperature, \(\alpha\) is the temperature coefficient, and \(T-T_0\) is the temperature change. The exact increase depends on the conductor's material and temperature range. Heating does not ordinarily cause copper resistance to decrease or become zero. Temperature must therefore be considered when interpreting precise resistance measurements and assessing conductor performance under load.


Question 20

A technician is checking an electrical motor control circuit. The contactor coil receives the correct rated voltage when a start command is given, but the contactor does not pull in. Which diagnostic direction is most appropriate after confirming that the voltage measurement is valid?

A. Replace the motor windings immediately because the motor must be preventing the contactor coil from receiving voltage.  B. Increase the supply voltage beyond the coil's rating to overcome any mechanical resistance in the contactor.  C. Disconnect the protective earth conductor because the contactor cannot operate while its protective connection remains intact.  D. Investigate the contactor coil, its mechanical movement, and any internal defect that could prevent operation despite the correct applied voltage.

Answer: D. Investigate the contactor coil, its mechanical movement, and any internal defect that could prevent operation despite the correct applied voltage.

Rationale: If the contactor coil is receiving its correct rated voltage but the contactor does not pull in, attention should turn to the coil itself and the contactor's mechanical condition. Possible causes include an open or damaged coil, a jammed armature, mechanical obstruction, or internal damage that prevents the magnetic mechanism from operating. The artisan should isolate the circuit before conducting resistance checks or inspecting the mechanism, and should follow the manufacturer's maintenance procedures. The motor windings are not the first suspect merely because the contactor fails to operate, since the control device should be investigated directly when the coil's supply has been verified. Applying a higher-than-rated voltage can damage the coil, while disconnecting the protective earth conductor does not correct the underlying fault and would compromise safety.


Question 21

During maintenance of a distribution board, an artisan notices that a protective device has operated, but the cause of the interruption is not immediately apparent. The circuit supplies several items of equipment. Which approach is most appropriate for distinguishing a faulty individual appliance from a fault in the fixed wiring?

A. Isolate the circuit, inspect the installation, and use a systematic process of testing the wiring and assessing connected equipment separately.  B. Replace the protective device with a higher-rated model and restore all loads simultaneously to identify which appliance operates first.  C. Disconnect the protective earth conductor and energise the circuit so that equipment faults become easier to distinguish.  D. Replace every connected appliance because operation of a protective device confirms that all loads have developed electrical defects.

Answer: A. Isolate the circuit, inspect the installation, and use a systematic process of testing the wiring and assessing connected equipment separately.

Rationale: A protective device operating does not by itself establish whether the cause lies in an individual appliance, the fixed wiring, an overload condition, or another abnormal operating condition. A systematic investigation begins by making the circuit safe, inspecting for visible defects, and conducting appropriate tests on the wiring and connected equipment. Depending on the protection involved and the initial findings, equipment may need to be disconnected and assessed separately so that the source of the fault can be identified without exposing personnel or equipment to unnecessary risk. Replacing the protective device with a higher-rated model can compromise protection and conceal the original problem. Disconnecting the protective earth conductor is unsafe, while replacing all appliances without evidence of individual faults is neither a sound diagnostic method nor an efficient maintenance response.


Question 22

A technician measures the voltage across a single-phase AC supply using a digital multimeter. The displayed value is approximately 230 V. Which interpretation is generally correct when the meter is configured for an appropriate AC voltage measurement?

A. The reading represents the maximum instantaneous voltage reached during each cycle of a sinusoidal supply.  B. The reading generally represents the RMS voltage, which expresses the equivalent heating effect of the AC voltage in a resistive load.  C. The reading represents the arithmetic average of all instantaneous voltage values over a complete symmetrical cycle.  D. The reading represents the peak-to-peak voltage, measured from the most negative to the most positive point of the waveform.

Answer: B. The reading generally represents the RMS voltage, which expresses the equivalent heating effect of the AC voltage in a resistive load.

Rationale: Standard AC voltage measurements are generally expressed as root-mean-square values, provided that the instrument is configured appropriately and the waveform falls within its measurement capabilities. The RMS value is particularly useful because it corresponds to the DC voltage that would produce the same average heating effect in a resistive load. For a pure sinusoidal waveform, an RMS voltage of approximately 230 V corresponds to a peak voltage of about \(230\sqrt{2}\), or 325 V, and a peak-to-peak voltage of approximately 650 V. The RMS value is not the same as the peak, peak-to-peak, or arithmetic average over a complete symmetrical sinusoidal cycle. Actual readings depend on the waveform and the meter's measurement method, so the instrument's specifications must be considered when measuring distorted or non-sinusoidal voltages.


Question 23

A motor operates normally for several minutes before its overload relay trips. The motor current is subsequently found to be higher than its rated full-load current under the observed operating conditions. Which interpretation is most appropriate?

A. The trip necessarily proves that the overload relay has failed, regardless of the motor's load and operating conditions.  B. The trip proves that the protective earth conductor has excessive resistance and must be replaced before any other investigation.  C. The motor may be experiencing sustained overload or another condition causing excessive current, so the load and motor operating conditions should be investigated.  D. The trip establishes that the supply frequency is exactly twice the motor's rated frequency during normal operation.

Answer: C. The motor may be experiencing sustained overload or another condition causing excessive current, so the load and motor operating conditions should be investigated.

Rationale: An overload relay is designed to protect a motor against sustained excessive current under the conditions for which the protection has been selected and configured. A motor that runs for several minutes before tripping, while drawing current above its rated full-load value, may be experiencing excessive mechanical load, binding or friction, incorrect operating conditions, or an electrical problem that increases current. The artisan should investigate the driven equipment, compare actual operating conditions with the motor's ratings, and verify the suitability and settings of the protective arrangement. The trip alone does not prove that the relay has failed or that the protective earth conductor is defective. It also provides no basis for concluding that the supply frequency has doubled. A correct diagnosis requires the operating conditions and measurements to be assessed together.


Question 24

A maintenance team is investigating repeated failures of electrical connections in equipment exposed to vibration. Inspection reveals that the connections become loose after periods of operation, even though they were initially tightened. Which maintenance improvement is most appropriate?

A. Apply the highest possible tightening force to every terminal, regardless of the manufacturer's specified torque.  B. Increase the circuit current temporarily so that the terminals heat up and establish more secure contact surfaces.  C. Eliminate all preventive inspections because initially correct tightening proves that future loosening cannot be predicted.  D. Investigate the effects of vibration, verify terminal suitability and specified tightening requirements, and implement appropriate measures to prevent recurrence.

Answer: D. Investigate the effects of vibration, verify terminal suitability and specified tightening requirements, and implement appropriate measures to prevent recurrence.

Rationale: Repeated loosening of electrical connections in equipment exposed to vibration indicates that the maintenance response should address the underlying mechanical and electrical conditions rather than simply repeat the same repair. The team should determine whether the terminals and connectors are suitable for the application, whether specified tightening torques have been followed, and whether the equipment requires approved vibration-resistant connection methods or other manufacturer-recommended measures. Excessive tightening can damage threads, deform terminals, or compromise the connection, while deliberately increasing current can create dangerous heating. Eliminating inspections would ignore a recurring defect that may lead to high-resistance connections, arcing, equipment failure, or fire. A preventive maintenance plan should incorporate the findings and verify whether corrective measures successfully prevent further loosening.


Question 25

An artisan is testing an isolated single-phase circuit after a suspected insulation fault. The insulation resistance between the phase conductor and protective earth is found to be significantly lower than the expected value. Before returning the circuit to service, which action is most appropriate?

A. Investigate the low insulation resistance, identify and correct the underlying defect, and repeat the required tests to verify that the circuit meets the applicable acceptance criteria.  B. Increase the circuit breaker's current rating because doing so will restore the insulation resistance of the affected conductor.  C. Accept the circuit immediately if the phase-to-neutral voltage is correct, because normal supply voltage establishes satisfactory insulation.  D. Disconnect the protective earth conductor permanently so that the insulation resistance measurement no longer indicates a fault to earth.

Answer: A. Investigate the low insulation resistance, identify and correct the underlying defect, and repeat the required tests to verify that the circuit meets the applicable acceptance criteria.

Rationale: A low insulation resistance between a phase conductor and protective earth may indicate damaged insulation, moisture, contamination, deteriorated cable material, a defective connected component, or another unintended conductive path. The circuit should remain isolated while the cause is investigated and corrected. The artisan should also confirm that the test arrangement is appropriate and that connected equipment has been treated in accordance with the applicable procedure. After repairs, the required insulation resistance and other relevant verification tests should be repeated to establish that the installation satisfies the applicable acceptance criteria before it is returned to service. Increasing the circuit breaker's rating does not repair insulation, and a normal phase-to-neutral voltage does not establish satisfactory insulation resistance. Disconnecting the protective earth conductor would compromise electrical safety rather than resolve the defect.

Question 26

A single-phase transformer has 1,000 turns on its primary winding and 200 turns on its secondary winding. The primary winding is supplied with 230 V AC. Assuming an ideal transformer, what secondary voltage should be expected?

A. 46 V, because the secondary voltage is proportional to the primary-to-secondary turns ratio.  B. 115 V, because the secondary winding has half the number of primary turns.  C. 920 V, because the primary voltage is multiplied by the primary-to-secondary turns ratio.  D. 1,150 V, because the secondary voltage increases as the number of turns decreases.

Answer: A. 46 V, because the secondary voltage is proportional to the primary-to-secondary turns ratio.

Rationale: For an ideal transformer, the ratio of primary voltage to secondary voltage equals the ratio of primary turns to secondary turns: \(V_p/V_s=N_p/N_s\). Rearranging gives \(V_s=V_p(N_s/N_p)\). Substituting the values gives \(V_s=230(200/1,000)=46\text{ V}\). The transformer is therefore a step-down transformer because its secondary winding has fewer turns than its primary winding. The other options result from incorrect use of the turns ratio or an incorrect assumption about the relationship between voltage and the number of turns. In a real transformer, the measured secondary voltage may differ slightly because of winding resistance, leakage reactance, and loading. The calculation assumes ideal operation and an appropriate AC supply.


Question 27

A three-phase motor is operating on a balanced supply. During maintenance, a technician discovers that the motor rotates in the opposite direction to the direction required by the driven equipment. Assuming the motor is suitable for reversal and no manufacturer-specific restriction applies, which action will normally reverse its direction of rotation?

A. Exchange the protective earth conductor with the neutral conductor at the motor terminals.  B. Increase the overload relay setting until the motor develops sufficient torque to rotate in the opposite direction.  C. Interchange any two of the three phase conductors using an approved isolation and reconnection procedure.  D. Reverse the polarity of the protective earth conductor while leaving all three phase connections unchanged.

Answer: C. Interchange any two of the three phase conductors using an approved isolation and reconnection procedure.

Rationale: The direction of rotation of a conventional three-phase induction motor depends on the phase sequence of its supply. Interchanging any two phase conductors reverses that sequence and normally reverses the motor's direction of rotation. The work must be performed after appropriate isolation and verification that the circuit is safe, and the technician should confirm that the driven equipment can safely operate in the intended direction before restarting it. Protective earth and neutral conductors must not be interchanged to reverse a motor, because they perform different functions and such a change could create a serious safety hazard. Increasing the overload relay setting does not reverse the phase sequence and could compromise motor protection. The phase connections must be restored and verified in accordance with the motor and installation requirements.


Question 28

A technician is inspecting a distribution transformer that supplies a group of consumers. The transformer has an unusually high operating temperature, although the ambient temperature is within its normal range. Which investigation would provide the most useful initial information about whether excessive loading is contributing to the problem?

A. Measure the resistance of the transformer enclosure and compare it with the resistance of the neutral conductor.  B. Measure the transformer load currents, compare them with its ratings, and assess the loading and phase balance against its design requirements.  C. Disconnect the transformer protective earthing arrangement and observe whether the enclosure temperature decreases.  D. Increase the secondary voltage above its specified value to determine whether the transformer temperature stabilises.

Answer: B. Measure the transformer load currents, compare them with its ratings, and assess the loading and phase balance against its design requirements.

Rationale: Excessive loading can increase winding losses and contribute to overheating in a distribution transformer. Measuring the load currents and comparing them with the transformer ratings helps establish whether the transformer is carrying more current than intended. In a three-phase installation, the phase currents should also be assessed for imbalance because uneven loading can contribute to unequal phase conditions and additional losses. Other possible causes of overheating include inadequate cooling, blocked ventilation, deteriorated insulation, internal defects, and unsuitable operating conditions, so load measurements are an initial diagnostic step rather than conclusive proof of the cause. Disconnecting protective earthing would create a safety risk and would not correct overheating. Increasing the secondary voltage beyond its specified value is not an appropriate diagnostic procedure because it can damage connected equipment and worsen operating conditions.


Question 29

An artisan is examining an electrical installation in which metal enclosures of fixed electrical equipment are connected to the protective earthing system. Which statement best explains the primary safety purpose of this arrangement?

A. It ensures that the normal operating current of every connected appliance returns through the metal enclosure.  B. It prevents all faults from occurring by maintaining the voltage of every conductor at exactly zero volts.  C. It increases the normal operating voltage supplied to equipment whenever the circuit carries a heavy load.  D. It provides a protective path for fault current and helps protective measures disconnect the supply when a dangerous fault occurs.

Answer: D. It provides a protective path for fault current and helps protective measures disconnect the supply when a dangerous fault occurs.

Rationale: Protective earthing connects exposed conductive parts of electrical equipment to the installation's protective earthing system so that, if a live conductor contacts a metal enclosure, a fault-current path is established. Depending on the earthing arrangement and protective devices, this path helps produce conditions that cause the supply to be disconnected within the required time. Protective earthing does not prevent every fault, does not guarantee that an enclosure will remain at exactly zero volts under all conditions, and is not intended to carry normal load current in an ordinary installation. It also does not increase the operating voltage of connected equipment. Effective protection depends on the integrity of the protective conductor, the earthing arrangement, the characteristics of the fault, and the operation of the associated protective measures.


Question 30

A technician is selecting a replacement cable for a circuit that carries a continuous load. The proposed cable has the correct conductor material and nominal cross-sectional area, but it will be installed in a hotter environment than the original cable. Why must the installation conditions be considered before approving the replacement?

A. Higher ambient temperature can reduce the cable's permissible current-carrying capacity because the conductor has less capacity to dissipate additional heat.  B. Higher ambient temperature necessarily increases the cable's permissible current-carrying capacity because the conductor becomes more electrically conductive.  C. A cable with the same cross-sectional area always has the same permissible current rating, regardless of installation method or surrounding conditions.  D. Ambient temperature affects insulation resistance only and has no relevance to conductor temperature or current-carrying capacity.

Answer: A. Higher ambient temperature can reduce the cable's permissible current-carrying capacity because the conductor has less capacity to dissipate additional heat.

Rationale: A cable's permissible current-carrying capacity depends on conductor size, insulation type, installation method, ambient temperature, grouping with other cables, and other applicable conditions. When the surrounding temperature increases, the cable has less temperature margin available before its conductor or insulation reaches its permitted operating limit. The allowable current may therefore need to be reduced using the appropriate correction factors and installation requirements. Selecting a cable solely on the basis of conductor material and cross-sectional area can result in overheating if the actual installation conditions are more demanding than those assumed in the original design. Higher temperature does not automatically increase permissible current capacity, and the effects extend beyond insulation resistance to include heat dissipation and the conductor's operating temperature.

📘 Get the Full Aptitude Test Questions PDF through your  Gmail (Questions 1–150)

You’ve just accessed the first 30 questions. The full set of 150 expertly prepared aptitude test questions for Artisan Grade II (Electrical) – TANESCO.,  Is available, pay, and get access.

To get access to the full PDF, please make a payment of Tsh 10,000 to the LIPA numbers below:

CRDB Lipa TANQR : 11692089
Airtel Money LIPA Number: 13970429
Yas/Tigo LIPA Number: 18401500
M-Pesa WAKALA:  826910
Registered Name: Johnson Yesaya Mgelwa

After payment, please send a text message to notify us of your payment:

Contact Number: +255 628 729 934

⚠️ Important Notice

  • The PDF will be watermarked with your name and phone number and protected for personal use only.
  • Redistribution, sharing, screenshotting, or copying the contents is strictly prohibited. When you share unlawfully, your name and phone number are visible and easy to trace as you leaked a document to other third parties.
  • Legal action may be taken against the misuse of this material.

Thank you for supporting quality content. Best of luck in your interview preparation!