“150”, Aptitude Test Questions and Answers for Technician Grade II (Electrical/Electronics) – TANESCO.

 “150”, Aptitude Test Questions and Answers for Technician Grade II (Electrical/Electronics) – TANESCO.

 

ABSTRACT

This preparation package contains 150 structured multiple-choice questions and answers designed to help candidates prepare for the Technician Grade II – Electrical/Electronics (TANESCO) aptitude test in Tanzania. The questions assess essential knowledge and practical understanding of electrical and electronic engineering, including power generation and distribution, electrical installations, transformers, motors, circuit protection, fault diagnosis, testing instruments, industrial automation, instrumentation and maintenance. They incorporate technical calculations, practical scenarios and closely related answer options to challenge candidates' analytical thinking, technical accuracy and problem-solving abilities. Each question is accompanied by a correct answer and an explanatory rationale to support effective learning, revision and examination preparation.

 

Prepared for: Candidates applying for Technician Grade II (Electrical/Electronics) – TANESCO

Independent aptitude-test preparation resource; not an official TANESCO publication.

0628729934.

Date: November 10, 2026

 

Dear applicants,

This collection of 150 multiple-choice questions and answers is designed to help candidates revise electrical trade knowledge relevant to aptitude tests and recruitment assessments for Technician Grade II (Electrical/Electronics) – TANESCO. It is an independent preparation resource, not an official TANESCO examination paper, and it does not guarantee that any question will appear in a recruitment assessment. I wish you success in your preparation and recruitment process!

 

Warm regards,

Technician Grade II (Electrical/Electronics) – TANESCO Aptitude Test Preparation Guide


Independent aptitude-test preparation guide for candidates applying for Technician Grade II (Electrical/Electronics) – TANESCO. Not an official TANESCO publication.

Technician Grade II (Electrical/Electronics) – TANESCO.

150 Aptitude Test Questions and Answers


Question 1. A three-phase electrical motor operates from a 400 V supply and draws a line current of 32 A at a power factor of 0.8 lagging. Assuming the motor operates under balanced conditions, what is the approximate active electrical input power?

A. 14.2 kW.
B. 16.8 kW.
C. 17.7 kW.
D. 22.2 kW.

Correct Answer: C. 17.7 kW.

Rationale: The active power consumed by a balanced three-phase load is calculated using \(P=\sqrt{3}V_LI_L\cos\phi\), where \(V_L\) represents line voltage, \(I_L\) represents line current and \(\cos\phi\) represents power factor. Substituting the given values gives \(P=1.732\times400\times32\times0.8=17,736.96\) watts, equivalent to approximately 17.7 kW. It is important to distinguish active power from apparent power, which would be approximately 22.2 kVA in this case. Multiplying voltage and current without considering the three-phase factor or power factor would produce an incorrect result. This calculation is particularly relevant when evaluating motor loading and electrical power consumption in industrial installations.


Question 2. A single-phase transformer has 660 turns in its primary winding and is supplied with 11,000 V. If the transformer is required to produce an ideal secondary voltage of 415 V, approximately how many turns should the secondary winding contain?

A. 25 turns.
B. 40 turns.
C. 55 turns.
D. 75 turns.

Correct Answer: A. 25 turns.

Rationale: The transformer voltage ratio is directly proportional to the ratio of the number of turns in the primary and secondary windings. The relationship is expressed as \(V_p/V_s=N_p/N_s\). Rearranging gives \(N_s=N_p(V_s/V_p)\). Therefore, \(N_s=660\times415/11000=24.9\), which is approximately 25 turns. A transformer designed to reduce voltage from 11 kV to 415 V is a step-down transformer because the secondary winding has considerably fewer turns than the primary winding. The calculation assumes an ideal transformer, meaning winding resistance, leakage reactance and other voltage losses are neglected. Understanding the relationship between voltage and winding turns is essential when assessing transformer specifications, winding arrangements and transformation ratios.


Question 3. A current transformer has a rated primary-to-secondary current ratio of 400/5 A. During an electrical installation test, the primary conductor carries a current of 240 A. What current should ideally be measured on the secondary side of the current transformer?

A. 2.0 A.
B. 2.4 A.
C. 4.0 A.
D. 3.0 A.

Correct Answer: D. 3.0 A.

Rationale: A current transformer reduces a high primary current to a proportionally smaller secondary current for measurement and protection purposes. Its transformation ratio is determined by dividing the rated primary current by the rated secondary current. In this case, the ratio is \(400/5=80\). Therefore, when the primary current is 240 A, the secondary current is \(240/80=3\) A. This is an ideal calculation that neglects the effects of excitation current and measurement errors. A particularly important practical consideration is that the secondary winding of an energized conventional current transformer must never be left open-circuited because a dangerously high voltage may develop across its terminals. Appropriate shorting arrangements must be used before disconnecting secondary instruments or protection circuits.


Question 4. A three-phase induction motor is designed to operate normally with its stator windings connected in delta. When the same motor is started using a star-delta starter, what happens to its starting line current compared with direct-on-line starting in delta, assuming the same supply voltage and negligible supply impedance?

A. It becomes approximately one-half of the original current.
B. It becomes approximately one-third of the original current.
C. It becomes approximately two-thirds of the original current.
D. It remains approximately equal to the original current.

Correct Answer: B. It becomes approximately one-third of the original current.

Rationale: In a star-delta starting arrangement, the motor windings are initially connected in star, meaning each winding receives a phase voltage equal to the line voltage divided by \(\sqrt{3}\). Since the impedance of each winding is assumed constant, the starting phase current is also reduced to approximately \(1/\sqrt{3}\) of its delta-connected value. In delta, line current is \(\sqrt{3}\) times phase current, whereas in star, line current equals phase current. Combining these relationships shows that the star-connected starting line current is approximately one-third of the direct-on-line delta starting line current. The starting torque also falls to approximately one-third because induction motor starting torque is approximately proportional to the square of the applied voltage. This distinction is important when selecting motor starting methods to reduce starting current and mechanical stress on electrical installations.


Question 5. A series RLC circuit is connected to a 50 Hz AC supply. If its inductance is 0.2 H, what capacitance will produce series resonance at the supply frequency?

A. 50.7 µF.
B. 63.7 µF.
C. 75.2 µF.
D. 100.5 µF.

Correct Answer: A. 50.7 µF.

Rationale: Series resonance occurs when the inductive reactance equals the capacitive reactance, resulting in zero net reactance and a purely resistive circuit under ideal conditions. The resonant frequency is given by \(f_r=1/(2\pi\sqrt{LC})\). Rearranging the formula gives \(C=1/(4\pi^2f_r^2L)\). Substituting \(f_r=50\) Hz and \(L=0.2\) H produces \(C=1/(4\pi^2\times50^2\times0.2)\), giving approximately \(50.66\times10^{-6}\) farads or 50.7 µF. At resonance, the inductive and capacitive reactances cancel each other, resulting in minimum circuit impedance and maximum current for a fixed applied voltage. This principle is important in electrical filtering, tuning circuits and power-system applications involving reactive components.


Question 6. A three-phase distribution circuit operates at 400 V and supplies a balanced load drawing 25 A at a power factor of 0.8 lagging. The resistance of each conductor is 0.18 Ω over the circuit length, while conductor reactance is negligible. What is the approximate voltage drop across the three-phase circuit?

A. 3.60 V.
B. 4.50 V.
C. 6.24 V.
D. 7.79 V.

Correct Answer: C. 6.24 V.

Rationale: For a balanced three-phase circuit with negligible conductor reactance, the approximate line-to-line voltage drop is calculated using \(\Delta V=\sqrt{3}I_LR\cos\phi\), where \(R\) is the resistance of one conductor over the complete circuit length. Substituting the given values gives \(\Delta V=1.732\times25\times0.18\times0.8=6.235\) V, which is approximately 6.24 V. This represents a voltage drop of about 1.56% of the 400 V supply. The power factor must be included because only the resistance-related component of the voltage drop is being considered. In actual electrical installations, conductor reactance, temperature-dependent resistance, installation conditions and applicable voltage-drop limits must also be considered when selecting conductor sizes. This calculation is particularly relevant to distribution networks and electrical installation design.


Question 7. A power transformer receives an electrical input of 50 kW while its total iron losses and copper losses under the existing operating condition are 0.8 kW and 1.2 kW respectively. What is the approximate operating efficiency of the transformer?

A. 92%.
B. 94%.
C. 95%.
D. 96%.

Correct Answer: D. 96%.

Rationale: Transformer efficiency is the ratio of useful output power to input power, expressed as a percentage. The total losses are obtained by adding iron losses and copper losses, giving \(0.8+1.2=2\) kW. The output power is therefore \(50-2=48\) kW. Applying the efficiency formula gives \(\eta=(48/50)\times100=96\%\). Iron losses mainly arise from hysteresis and eddy currents in the transformer core and are approximately constant at a fixed voltage and frequency, whereas copper losses are caused by winding resistance and vary approximately with the square of the load current. Understanding these losses helps technicians assess transformer performance, investigate abnormal heating and identify operating conditions that may reduce energy efficiency.


Question 8. An electrical technician is selecting a circuit breaker for an installation where the prospective short-circuit current at the point of installation has already been established. Which characteristic of the circuit breaker must be adequate to ensure that it can safely interrupt the maximum prospective fault current?

A. Rated short-time withstand current.
B. Rated breaking capacity.
C. Rated making capacity.
D. Rated continuous current.

Correct Answer: B. Rated breaking capacity.

Rationale: The breaking capacity of a circuit breaker represents its ability to safely interrupt a specified fault current under defined test conditions without suffering unacceptable damage or creating an unsafe condition. When selecting a circuit breaker, its rated breaking capacity must be equal to or greater than the prospective short-circuit current at the installation point, with the applicable rating and standard taken into account. Rated continuous current serves a different purpose because it indicates the current the breaker is designed to carry under specified conditions during normal operation. Rated operational voltage concerns the voltage at which the device is intended to operate, while rated insulation voltage relates to its insulation characteristics. A breaker may have an adequate continuous current rating but still be unsuitable if its breaking capacity is insufficient for the available fault current.


Question 9. A power transformer is protected by a differential protection system. During an internal winding fault, the currents measured by the current transformers installed on the primary and secondary sides become unequal after the protection system has compensated for their respective ratios and phase displacement. What is the most appropriate interpretation of this condition?

A. The transformer may have developed an internal fault within its protected zone.
B. The transformer is experiencing a normal increase in magnetising current.
C. The transformer secondary load has developed a balanced operating condition.
D. The transformer is experiencing an external fault outside its protected zone.

Correct Answer: A. The transformer may have developed an internal fault within its protected zone.

Rationale: Transformer differential protection operates on the principle of comparing currents entering and leaving a defined protection zone. Under normal operating conditions and during external faults, properly compensated current measurements should approximately balance, meaning the differential current remains below the protection operating threshold. However, an internal fault such as a winding-to-winding fault or winding-to-earth fault can produce a significant difference between the compensated currents, causing the differential relay to issue a trip command. The system must account for transformer ratio differences, phase displacement, CT characteristics and possible transient effects to avoid unwanted operation. A genuine differential fault condition is therefore an indication requiring investigation rather than an ordinary change in transformer loading. This protection arrangement is particularly important for major transformers in transmission and distribution substations.


Question 10. An earth-leakage protection device is installed in a single-phase electrical circuit supplying an industrial appliance. During operation, the current flowing through the live conductor is greater than the current returning through the neutral conductor. Which principle explains how the device detects the abnormal condition?

A. It detects an increase in current above the circuit's rated overload setting.
B. It detects a reduction in insulation resistance between live conductors.
C. It detects an imbalance between the outgoing and returning currents.
D. It detects an increase in current flowing through the protective conductor.

Correct Answer: C. It detects an imbalance between the outgoing and returning currents.

Rationale: A residual current device (RCD) detects leakage by comparing the current flowing through the live conductor with the current returning through the neutral conductor. Under normal operating conditions, these currents should be equal in magnitude and opposite in direction. If part of the current escapes through an unintended path, such as an earth conductor or a person in contact with an exposed conductive part, the returning current becomes smaller than the outgoing current. This difference creates a residual current that can cause the RCD to disconnect the circuit when its operating threshold and time requirements are reached. An RCD is primarily intended to provide protection against residual-current faults and is not automatically a substitute for overcurrent protection. Understanding this distinction is essential when selecting and testing protective devices in electrical installations.


Question 11. During scheduled maintenance of a low-voltage electrical installation, a technician is required to determine whether the insulation between the live conductors and earth has deteriorated. Which testing instrument is most appropriate for this particular assessment?

A. Earth fault loop impedance tester.
B. Continuity resistance tester.
C. Residual current device tester.
D. Insulation resistance tester.

Correct Answer: D. Insulation resistance tester.

Rationale: An insulation resistance tester, commonly known as a megohmmeter, is designed to measure the resistance of electrical insulation by applying a specified DC test voltage and measuring the resulting leakage current. It is particularly useful when assessing insulation between conductors, between live conductors and earth, and across appropriate electrical equipment insulation systems. A low insulation resistance reading may indicate moisture ingress, contamination, physical insulation damage or deterioration caused by ageing and thermal stress. The installation must be safely isolated, verified dead and appropriately prepared before testing, with sensitive electronic equipment disconnected where necessary to prevent damage. A clamp meter measures current, a frequency meter measures supply frequency, and a phase-sequence meter identifies phase rotation; none of these instruments is intended to provide a direct insulation resistance assessment.


Question 12. An oscilloscope is connected to an electrical signal through a probe configured with a 10:1 attenuation ratio. The oscilloscope displays a peak voltage of 2.4 V, and the probe attenuation factor has not been compensated for in the oscilloscope settings. What is the actual peak voltage of the measured signal?

A. 0.24 V.
B. 24 V.
C. 12 V.
D. 240 V.

Correct Answer: B. 24 V.

Rationale: A 10:1 oscilloscope probe reduces the voltage reaching the oscilloscope input to one-tenth of the actual signal voltage. Therefore, when the displayed peak voltage is 2.4 V and the instrument has not automatically compensated for the probe attenuation, the actual signal voltage is obtained by multiplying the displayed value by ten. Thus, \(V_{\text{actual}}=2.4\times10=24\) V. This distinction is important because oscilloscope probes are designed to allow measurements of higher voltages while reducing loading effects on the circuit being tested. The technician must ensure that the probe attenuation setting and oscilloscope channel configuration correspond correctly; otherwise, the measured voltage may be interpreted incorrectly. The probe's voltage rating, frequency response and grounding arrangements must also be considered before taking measurements.


Question 13. A single-phase full-wave bridge rectifier is supplied from a 50 Hz AC source. Assuming ideal diodes and a continuous periodic input waveform, what is the frequency of the principal rectified output ripple?

A. 25 Hz.
B. 50 Hz.
C. 100 Hz.
D. 200 Hz.

Correct Answer: C. 100 Hz.

Rationale: A full-wave bridge rectifier converts both the positive and negative half-cycles of an AC waveform into output pulses of the same polarity. Consequently, the rectified waveform produces two output pulses during every complete AC cycle. The ripple frequency is therefore twice the input supply frequency. For a 50 Hz source, \(f_{\text{ripple}}=2\times50=100\) Hz. This differs from a half-wave rectifier, which produces one output pulse per input cycle and therefore has a ripple frequency equal to the supply frequency. Understanding this difference is important when designing and troubleshooting DC power supplies, particularly when assessing smoothing capacitor performance, ripple voltage and the operation of electronic equipment supplied by rectified AC.


Question 14. A bipolar junction transistor operating in its active region has a measured collector current of 4 mA and a base current of 40 µA. What is the approximate DC current gain of the transistor?

A. 100.
B. 80.
C. 60.
D. 40.

Correct Answer: A. 100.

Rationale: The DC current gain of a bipolar junction transistor in the common-emitter configuration is represented by beta, expressed as \(\beta=I_C/I_B\), where \(I_C\) is collector current and \(I_B\) is base current. Converting the base current into milliamperes gives 40 µA = 0.04 mA. Therefore, \(\beta=4/0.04=100\). This means that, under the stated operating conditions, the collector current is approximately 100 times the base current. The current gain is not necessarily constant under all operating conditions because it can vary with collector current, temperature and the characteristics of the transistor. This principle is relevant to electronic switching circuits, amplification stages and fault diagnosis involving transistor-based control equipment.


Question 15. An operational amplifier is connected in a non-inverting amplifier configuration. Its feedback resistor is 90 kΩ, while the resistor connected between the inverting input and ground is 10 kΩ. Assuming ideal operational amplifier characteristics, what is the closed-loop voltage gain?

A. 8.
B. 9.
C. 11.
D. 10.

Correct Answer: D. 10.

Rationale: The voltage gain of an ideal non-inverting operational amplifier is calculated using \(A_v=1+R_f/R_1\), where \(R_f\) is the feedback resistance and \(R_1\) is the resistance between the inverting input and ground. Substituting the values gives \(A_v=1+(90,000/10,000)=1+9=10\). The non-inverting configuration produces an output signal that maintains the same phase as the input signal, while its voltage gain is determined by the feedback resistor network. A common source of error is using the inverting amplifier gain formula, which has a different expression and produces a different phase relationship. Operational amplifiers are widely used in signal conditioning, instrumentation, measurement systems and electronic control circuits.


Question 16. In an industrial electrical control installation, several field sensors are connected to a programmable logic controller (PLC). What is the principal function of the PLC input module in this arrangement?

A. To convert the controller's processed logic into signals for external actuators.
B. To receive and condition signals from field input devices.
C. To execute the programmed instructions and determine control decisions.
D. To provide regulated electrical power to the controller's processing circuits.

Correct Answer: B. To receive and condition signals from field input devices.

Rationale: A PLC input module acts as the interface between external field devices and the programmable controller's processing system. It receives signals from devices such as limit switches, pressure switches, proximity sensors, temperature transmitters and other monitoring equipment. Depending on the input module design, it may accept digital signals, analogue voltage signals or analogue current signals and provide the necessary signal conditioning, electrical isolation and conversion for the controller to process the information. The PLC's central processing unit then executes the programmed logic and determines the appropriate output response. The output module, rather than the input module, interfaces with actuators and other controlled devices. This distinction is important when installing, commissioning and diagnosing industrial automation and electrical control systems.


Question 17. A pressure transmitter uses a standard 4–20 mA output signal to represent a measurement range of 0–100 bar. During operation, the measured output current is 12 mA. What pressure value is being represented by the transmitter?

A. 25 bar.
B. 40 bar.
C. 50 bar.
D. 75 bar.

Correct Answer: C. 50 bar.

Rationale: A 4–20 mA instrumentation signal uses 4 mA as the lower range value and 20 mA as the upper range value. The difference between these values is 16 mA, representing the full measurement span of 100 bar. At a measured current of 12 mA, the signal is 8 mA above the lower range value. This represents \(8/16=0.5\), or 50% of the measurement span. Therefore, the pressure is \(0.5\times100=50\) bar. The correct calculation must use the 4 mA lower reference rather than treating zero pressure as zero current. The 4 mA starting point is commonly known as a live zero, allowing a monitoring system to distinguish a valid zero measurement from certain circuit faults, such as an open transmitter loop.


Question 18. A platinum resistance temperature detector (RTD) is specified as a PT100 sensor conforming to the IEC 60751 characteristic. What is the approximate resistance of this sensor at 100°C?

A. 138.5 Ω.
B. 120.0 Ω.
C. 150.0 Ω.
D. 100.0 Ω.

Correct Answer: A. 138.5 Ω.

Rationale: A PT100 is a platinum resistance temperature detector whose nominal resistance is 100 Ω at 0°C. Its resistance increases predictably as temperature rises, allowing temperature to be determined through electrical resistance measurement. According to the standard IEC 60751 characteristic, the approximate resistance at 100°C is 138.5 Ω. This relationship is commonly expressed using the Callendar–Van Dusen equation, which accounts for the temperature-dependent behaviour of platinum. Unlike a thermocouple, which generates a small thermoelectric voltage due to a temperature difference, an RTD operates by changing its resistance with temperature. PT100 sensors are widely applied in industrial instrumentation, transformer temperature monitoring, motor protection and process-control systems. Accurate resistance measurement and appropriate lead-wire compensation are important when using these sensors.


Question 19. A three-phase induction motor is operating under normal load when one of its supply phases becomes disconnected due to a faulty connection. The motor continues rotating, but its operating condition becomes abnormal. Which consequence is most likely to occur if the condition is not corrected?

A. The remaining phase currents increase, potentially causing excessive winding heating.
B. The motor continues operating normally because the remaining phases maintain a balanced rotating field.
C. The motor develops increased starting torque because the supply voltage is redistributed between phases.
D. The motor's synchronous speed increases because the number of supplied phases has decreased.

Correct Answer: A. The remaining phase currents increase, potentially causing excessive winding heating.

Rationale: The loss of one supply phase in a three-phase induction motor is known as single-phasing. When this condition occurs while the motor is already running, the motor may continue rotating because of its existing momentum and the remaining electromagnetic torque. However, the motor's magnetic field becomes unbalanced, and the currents in the remaining phases can increase significantly as the motor attempts to maintain its mechanical load. This excessive current produces additional \(I^2R\) losses in the stator windings, resulting in overheating and potentially severe insulation damage or complete motor failure. The motor may also experience reduced torque, increased vibration and abnormal noise. Appropriate phase-failure protection and overload protection are therefore important in industrial motor installations. A technician should investigate the supply connections, fuses, contactor contacts and protective devices rather than allowing the motor to continue operating under this condition.


Question 20. A synchronous generator is designed with four magnetic poles and operates at a frequency of 50 Hz. What is its corresponding synchronous rotational speed?

A. 750 rpm.
B. 1,000 rpm.
C. 3,000 rpm.
D. 1,500 rpm.

Correct Answer: D. 1,500 rpm.

Rationale: The synchronous speed of an AC generator is determined by its electrical frequency and number of magnetic poles. The relationship is \(N_s=120f/P\), where \(N_s\) is synchronous speed in revolutions per minute, \(f\) is frequency in hertz and \(P\) is the total number of poles. Substituting the given values gives \(N_s=(120\times50)/4=1,500\) rpm. This means a four-pole synchronous generator must rotate at 1,500 rpm to produce an electrical frequency of 50 Hz. A two-pole generator operating at the same frequency would require 3,000 rpm, while an eight-pole generator would operate at 750 rpm. This relationship is particularly important in power generation because generator rotational speed and pole configuration determine the frequency of the generated electricity.


Question 21. A three-phase induction motor has a rated mechanical output power of 7.5 kW. It operates from a 400 V supply with a power factor of 0.8 and an efficiency of 90%. Assuming balanced operation, what is the approximate line current drawn by the motor at its rated output?

A. 12.5 A.
B. 15.0 A.
C. 17.2 A.
D. 21.7 A.

Correct Answer: B. 15.0 A.

Rationale: The rated output power of an electric motor represents the mechanical power delivered at its shaft, whereas the electrical input power is greater because of motor losses. The input power is calculated by dividing the output power by efficiency: \(P_{\text{in}}=7,500/0.9=8,333.33\) W. For a balanced three-phase motor, the electrical input power is \(P_{\text{in}}=\sqrt{3}V_LI_L\cos\phi\). Rearranging to determine line current gives \(I_L=P_{\text{out}}/(\sqrt{3}V_L\cos\phi\eta)\). Substituting the values gives \(I_L=7,500/(1.732\times400\times0.8\times0.9)=15.03\) A, approximately 15.0 A. The efficiency factor must be included because the stated 7.5 kW is mechanical output rather than electrical input. This calculation is important when selecting motor protection, conductors and associated electrical equipment.


Question 22. An industrial installation consumes 20 kW of active power at a lagging power factor of 0.70. An electrical technician proposes installing a capacitor bank to improve the power factor to 0.95 lagging without changing the active power demand. What is the approximate reactive power rating of the capacitor bank required?

A. 8.20 kVAr.
B. 10.50 kVAr.
C. 13.83 kVAr.
D. 18.20 kVAr.

Correct Answer: C. 13.83 kVAr.

Rationale: Power factor correction involves reducing the reactive power drawn from the supply by introducing capacitive reactive power to compensate for the inductive reactive power of the installation. The required capacitor rating is calculated using \(Q_c=P(\tan\phi_1-\tan\phi_2)\), where \(P\) is active power, \(\phi_1\) is the original power-factor angle and \(\phi_2\) is the corrected power-factor angle. For the original power factor of 0.70, \(\tan\phi_1\) is approximately 1.0202, while for the improved power factor of 0.95, \(\tan\phi_2\) is approximately 0.3287. Therefore, \(Q_c=20(1.0202-0.3287)=13.83\) kVAr. The capacitor bank supplies approximately 13.83 kVAr of capacitive reactive power. Proper power factor correction reduces unnecessary reactive current in the supply network, improves voltage conditions and may reduce demand-related electricity costs. However, capacitor bank selection must also consider harmonics, switching arrangements and the risk of overcompensation.


Question 23. A 12.6 V battery is supplying a load drawing a current of 10 A. When the battery is delivering this current, its measured terminal voltage falls to 12.0 V. Assuming the battery's internal resistance remains constant, what is its approximate internal resistance?

A. 0.012 Ω.
B. 0.040 Ω.
C. 0.100 Ω.
D. 0.060 Ω.

Correct Answer: D. 0.060 Ω.

Rationale: When a battery supplies current to an external load, a voltage drop occurs across its internal resistance. The terminal voltage during discharge is given by \(V=E-Ir\), where \(E\) represents the electromotive force, \(I\) represents the discharge current and \(r\) represents internal resistance. Rearranging gives \(r=(E-V)/I\). Substituting the values produces \(r=(12.6-12.0)/10=0.6/10=0.06\) Ω. Therefore, the internal resistance is approximately 0.060 Ω. This calculation demonstrates why the terminal voltage of a battery under load can be lower than its open-circuit voltage. Excessive internal resistance may indicate battery deterioration, poor internal connections or other problems affecting its ability to deliver current. Such measurements are useful when investigating battery performance in backup power supplies, control systems and substation auxiliary DC systems.


Question 24. Two protective circuit breakers are installed in series within a low-voltage distribution system. The downstream breaker supplies a final distribution circuit, while the upstream breaker protects the main distribution board. When a short-circuit fault occurs on the final circuit, which arrangement best describes the desired protection coordination between the two breakers?

A. Both breakers should disconnect simultaneously for every fault condition.
B. The downstream breaker should clear the fault while the upstream breaker remains closed.
C. The upstream breaker should disconnect first to isolate the entire installation.
D. The downstream breaker should remain closed while the upstream breaker interrupts the fault.

Correct Answer: B. The downstream breaker should clear the fault while the upstream breaker remains closed.

Rationale: This arrangement is an example of selective coordination, also known as discrimination, between protective devices. Its purpose is to ensure that the protective device closest to a fault operates first, thereby isolating only the affected section of the electrical installation while maintaining supply to unaffected circuits. When a short circuit occurs downstream, the final circuit breaker should interrupt the fault current without unnecessarily causing the upstream main breaker to trip. Achieving this requires appropriate selection of breaker characteristics, current ratings, time-current curves and short-circuit performance. Depending on the devices and system design, manufacturers may also provide tested selectivity tables to establish whether full or partial discrimination is achieved. Poor coordination can result in unnecessary interruption of electricity to a larger part of the installation, increasing downtime and affecting connected equipment.


Question 25. In a low-voltage electrical installation, the protective earthing conductor connects exposed conductive parts of electrical equipment to the installation's earthing system. What is the principal safety purpose of this arrangement?

A. To provide a low-impedance fault-current path that facilitates automatic disconnection.
B. To provide the normal return path for current flowing through electrical loads.
C. To maintain the rated operating voltage across the equipment during normal operation.
D. To prevent excessive current from flowing through the neutral conductor during normal operation.

Correct Answer: A. To provide a low-impedance fault-current path that facilitates automatic disconnection.

Rationale: Protective earthing is intended to reduce the risk of electric shock when an insulation failure causes a live conductor to come into contact with an exposed conductive part of electrical equipment. The protective conductor provides a suitably low-impedance path for the resulting fault current, allowing the associated protective device, such as a fuse, circuit breaker or appropriate residual-current protection arrangement, to disconnect the supply within the required time. Without an effective protective earthing arrangement, an exposed metal enclosure could remain at a dangerous voltage, creating a serious shock hazard to anyone touching it. Protective earthing must not be confused with the normal neutral-current return path because the protective conductor is not intended to carry normal load current. Its design and installation must comply with the applicable electrical installation requirements, including appropriate conductor sizing, continuity and earthing arrangements. This is a fundamental safety consideration in TANESCO-related electrical installation and maintenance work.


Question 26. During a routine transformer open-circuit test, the high-voltage winding is left open while rated voltage is applied to the low-voltage winding. Which transformer characteristic is primarily determined from this test?

A. Full-load copper loss and percentage impedance.
B. Core (iron) loss and no-load current.
C. Full-load voltage regulation and winding temperature.
D. Short-circuit impedance and maximum fault current.

Correct Answer: B. Core (iron) loss and no-load current.

Rationale: The open-circuit test is conducted by applying rated voltage to one winding, usually the low-voltage winding, while keeping the other winding open. Since the transformer draws only a small no-load current, copper losses are relatively small and can generally be neglected. The wattmeter reading therefore approximates the core or iron losses, while the ammeter measures the no-load current. The test helps assess the transformer's magnetic performance and core condition.


Question 27. An electrical cable has a measured resistance of 0.8 Ω at 20°C. If the conductor is made of copper with a temperature coefficient of resistance of 0.00393 per °C at 20°C, what will its approximate resistance be when its temperature rises to 70°C?

A. 0.920 Ω. B. 0.957 Ω. C. 1.024 Ω. D. 1.157 Ω.

Correct Answer: B. 0.957 Ω.

Rationale: The resistance of a metallic conductor increases as its temperature rises because increased atomic vibration creates greater opposition to the movement of electrical charge carriers. For a temperature range where the linear approximation is appropriate, resistance is calculated using \(R_t=R_{20}[1+\alpha_{20}(t-20)]\). Here, \(R_{20}=0.8\) Ω, \(\alpha_{20}=0.00393\) per °C and the temperature increase is \(70-20=50\)°C. Therefore, \(R_{70}=0.8[1+(0.00393\times50)]=0.8(1.1965)=0.9572\) Ω. This gives approximately 0.957 Ω. The calculation demonstrates why conductor resistance measured under cold conditions cannot always be used directly to assess operating losses under normal loading. Temperature effects are important when evaluating cable voltage drop, power losses, overheating and electrical installation performance.


Question 28. Before connecting two three-phase transformers in parallel, a technician performs a polarity and phase-displacement verification. What is the main purpose of this verification?

A. To confirm that the transformers have identical core losses.
B. To ensure that their secondary voltages are in the correct phase relationship.
C. To establish that both transformers have equal winding temperatures.
D. To determine the insulation resistance of their neutral conductors.

Correct Answer: B. To ensure that their secondary voltages are in the correct phase relationship.

Rationale: When transformers operate in parallel, their voltage ratios, polarity, phase sequence and phase displacement must be compatible. Incorrect polarity or phase displacement can produce substantial circulating currents or even short-circuit conditions when the secondary windings are connected together. Verifying the phase relationship helps ensure safe and satisfactory parallel operation. Other important parallel-operation requirements include compatible voltage ratios and percentage impedances.


Question 29. An induction motor experiences a sustained overload that causes its current to remain above the normal operating value. Which component of a conventional thermal-magnetic motor protection arrangement is primarily responsible for responding to this condition?

A. The thermal overload element, which responds to the heating effect of excessive current.
B. The magnetic instantaneous element, which responds to normal starting current.
C. The contactor auxiliary contact, which measures motor winding temperature.
D. The circuit breaker's making mechanism, which regulates motor operating current.

Correct Answer: A. The thermal overload element, which responds to the heating effect of excessive current.

Rationale: A thermal overload element protects a motor against sustained excessive current by responding to the heating effect produced by the overload. Depending on its design, it may use a bimetallic element or an electronic sensing arrangement to initiate tripping. The magnetic instantaneous element is primarily intended to respond rapidly to high short-circuit currents rather than ordinary sustained overloads. A contactor auxiliary contact does not directly measure winding temperature, and a circuit breaker's making mechanism is not designed to regulate motor current.


Question 30. A three-phase synchronous generator operates at a constant mechanical speed and supplies an isolated electrical load. The connected load suddenly increases while the mechanical input power initially remains unchanged. What is the most likely immediate effect on the generator?

A. The generated frequency increases because the electrical demand is higher.
B. The generator automatically maintains its original frequency without any transient change.
C. The generated frequency tends to decrease because the electrical load torque increases.
D. The terminal voltage increases because the armature current becomes larger.

Correct Answer: C. The generated frequency tends to decrease because the electrical load torque increases.

Rationale: In an isolated synchronous generator, electrical frequency is directly related to the rotational speed of the rotor and the number of magnetic poles. When the electrical load increases, the generator experiences a corresponding increase in electromagnetic torque opposing the prime mover. If the mechanical input power does not immediately increase, the rotor experiences a decelerating effect and its speed tends to fall, resulting in a temporary reduction in generated frequency. The governor or prime-mover control system must respond by increasing mechanical input power to restore the rotor speed and maintain the required frequency. Excitation control performs a different function because it primarily regulates terminal voltage and reactive power behaviour. This distinction is important in understanding generator load response and frequency regulation in isolated generation systems.

📘 Get the Full Aptitude Test Questions PDF through your  Gmail (Questions 1–150)

You’ve just accessed the first 30 questions. The full set of 150 expertly prepared aptitude test questions for Technician Grade II (Electrical/Electronics) – TANESCO.,  Is available, pay, and get access.

To get access to the full PDF, please make a payment of Tsh 10,000 to the LIPA numbers below:

CRDB Lipa TANQR : 11692089
Airtel Money LIPA Number: 13970429
Yas/Tigo LIPA Number: 18401500
M-Pesa WAKALA:  826910
Registered Name: Johnson Yesaya Mgelwa

After payment, please send a text message to notify us of your payment:

Contact Number: +255 628 729 934

⚠️ Important Notice

  • The PDF will be watermarked with your name and phone number and protected for personal use only.
  • Redistribution, sharing, screenshotting, or copying the contents is strictly prohibited. When you share unlawfully, your name and phone number are visible and easy to trace as you leaked a document to other third parties.
  • Legal action may be taken against the misuse of this material.

Thank you for supporting quality content. Best of luck in your interview preparation!